Southern Star Central Gas Pipeline Midwest &
Mid-Continent Regions, United States
Providing corrosion control and system integrity services since 2003. Development
of standards, procedures, forms and IMP documents. Provided
project management oversight of ECDA Inspections. Assisted in the implementation
of their Integrity Management Plan. ENE was also present and
provided support for their jurisdictional IMP audit with PHMSA. Provided
training to field personnel on their integrity management program. Performed
a risk-based remote control valve study of their transmission
system based on system pressures, size, MAOP, and %SMYS.
Vectren Energy Upper Midwest, United States
An ongoing multi-year contract to provide Integrity Management Program
support for both gas and liquid lines including: integrity management plan
and procedure revisions, data gathering and research, MAOP origination
studies and regulatory guidance. Performed a risk-based remote control
valve study of their transmission system based on system pressures, size,
MAOP, and %SMYS.
Nicor Gas Illinois
Multi-year contract providing corrosion control, cathodic protection and
integrity management services since 2002. Primary responsibilities are
corrosion services and system integrity programming for Nicors transmission
and underground storage system facilities. Other responsibilities
include ECDA work; providing integrity management regulatory support;
and cathodic protection design and troubleshooting on distribution system
facilities.
DTE Energy Company Michigan
Provided External Corrosion Direct Assessment project management support.
This included project planning, technical guidance, data analysis and
development of paperwork necessary for regulatory review. ENE also provided,
as a part of this contract, project management for Internal Corrosion
Direct Assessment. ENE developed company Direct Assessment procedures;
reviewed and recommended changes of their existing Integrity Management
Plan; and performed a risk-based remote control valve study of their
transmission system based on system pressures, size, MAOP, and %SMYS.
Dominion Transmission West Virginia
Develop a risk assessment framework and model to rank over 1000 drip
tanks located along transmission lines and in storage fields. Project involved
identifying critical factors contributing to internal corrosion and using commercially
available software to generate a relative risk model for targeted
inspection and effective use of capital.
Ameren Services Company Illinois
Direct Assessment of excavated pipelines within their system. At the excavation
site, ENE evaluated the condition of the pipe; obtained samples
to determine the existence of MIC, pH of the soil, pH of water if present;
condition of coating; wall loss if any; extent of any corrosion or damage;
and the general condition of the pipe.
Illinois Power Company Illinois
Interpretation of data analysis on the chemical characterization of fluid
samples taken from their methane piping systems. The data was assessed
for risk of internal corrosion, and recommendations were made for further
monitoring.
Ameren Services Company Illinois
Development of an internal corrosion testing plan for natural gas storage
fields. ENE conducted a site audit and followed with the development
of a monitoring plan.
United States Gypsum (USG) United States
Providing system integrity support including: corrosion control and cathodic
protection performance and quality audit. Developed standards,
procedures, forms and IMP documents. Assisted in the implementation
of their Integrity Management Plan. Performed an ECDA assessment.
Provided complete support of all aspects of DOT 49 CFR Part 192.
Developed and implemented an Operator Qualification program which
included providing OQ training, and data management of their employee
training records and recertification documentation.
Empire Pipeline - New York
Field survey and design of corrosion control and stray current mitigation for new 77 mile high pressure transmission pipeline. Work involved field survey including aggregation and evaluation of data highlighting suspected anomalies for client.
Enbridge Energy United States and Canada
Multi-year contract to providing corrosion control engineering support
and annual compliance survey services for all of Enbridges northern
U.S. petroleum and natural gas transmission pipelines. Support includes:
corrosion control and cathodic protection engineering, troubleshooting,
repair, and design; construction and maintenance inspection
services; corrosion procedures development and review; and specialty
corrosion surveys.
We Energies Wisconsin
Performed external corrosion direct assessment (ECDA) for We Energies.
The assessment included pre-assessment confirmation, indirect
inspection including project management, and technical oversight and
assistance with Direct Assessment.
Aux Sable Liquid Products Midwest United States
An on-going multi-year contract to provide integrity management,
corrosion and cathodic protection support. Provided Integrity Management
Plan support including: plan facilitation; standards, procedures
and forms development and review; development of IMP documents;
and risk algorithm and risk modeling. Developed Operations and
Maintenance Manual, Operator Qualification Manual, and Public Awareness
Plan. Provided project management support and inspection services
related to in-line inspection. Cathodic protection annual surveys,
close-interval surveys and troubleshooting.
Mid American Energy Iowa
Close interval, depth of cover and ECDA survey of 150 miles of pipeline
located in rural and urban areas throughout Iowa.
MidAmerican Energy Iowa
Provided engineering support and services for cathodic protection design
and A/C mitigation along a 12.9 mile stretch of 16-inch natural gas
pipeline. This work included: cathodic protection and A/C mitigation
field survey, data analysis, cathodic protection design, and A/C mitigation
and decoupling recommendations.
Bonneville Power Montana
Performed cathodic protection assessment at their sub-station. Field work
and testing included: soil sampling, soil resistivities, electrical grid corrosion
assessment, and ground level atmospheric corrosion survey on above
grade structures. The review also included a report with an overall summary
of the cathodic protection system and recommendations.
Citgo-West Shore Pipeline Illinois, Indiana, and Wisconsin
Provide corrosion control engineering support and direct assessment
services for a multi-year contract. This includes: corrosion control and
cathodic protection engineering and design; construction and maintenance
inspection services; troubleshooting and repair of CP systems; specialty
corrosion surveys; corrosion procedures development and review; and
atmospheric surveys of above ground storage tanks and pipeline facilities.
Oklahoma Natural Gas Oklahoma
Provided technical expertise and development of IMP support documents,
preventative mitigation and response documents, and third-party review of
company integrity management plans. Also performed evaluation of current
data reporting process as it relates to IMP risk management data.
Tyson Foods Kansas
Due diligence evaluation and assessment of inactive line prior to sale transfer.
Work involved pre-assessment of existing records, CIS, DCVG survey
and confirmation of identified anomalies, which resulted in a hydrotest of
10 miles of 8 pipeline.
We Energies Wisconsin
Work with utility to trouble shoot and repair backlog of down reads. Project
involved short locating and current requirement testing as well as identifying
corrective actions for each location identified.
Integrys / Wisconsin Public Service Wisconsin
Field survey and design of corrosion control and stray current mitigation
for 56 miles of new high pressure transmission pipeline laterals from the
main pipeline to WPS town border stations.
Valero/Premcor Indiana
Performed interference testing on a 20 pipeline. Also evaluated the existing
cathodic protection system to determine if a new system was required,
including design and installation of the new system. Performed a close
interval survey of the line to verify the new system was providing adequate
protection.
Alvord, Burdick & Howson Illinois
Performed a multi year contract to provide cathodic protection analysis
and design for large diameter water pipeline transmission mains. The
contract included corrosion control monitoring and testing including test
point readings, continuity testing, Panhandle Eastern testing and close interval
survey. Testing was performed after installation at 6 months and 12
months.
Enbridge Ohio
Atmospheric corrosion evaluations were performed at 33 above grade locations
on a 16 diameter pipeline. The purpose of the survey was to document
locations that do not meet the federal requirements for atmospheric
corrosion. Once found, evaluations were performed to identify, assess and
document current conditions, based on risk rank.
Alliant Energy Iowa
Evaluation and design of a cathodic protection system for a 5 mile long,
10 gas line sharing a right-of-way with high voltage power lines. Evaluation
included soil resistivity analysis, identification of AC sources and
their maximum operation capacity, and of existing cathodic protection
rectifiers. A cathodic protection system was designed to adequately
protect the line.
Alliant Energy Iowa
Provided engineering support and services for an A/C mitigation study
for a 13 mile stretch of 20 natural gas pipeline. This study included the
field survey, data analysis, PRCI modeling and recommendations for
mitigation and decoupling designs.
West Shore Pipeline Illinois and Wisconsin
Atmospheric corrosion evaluations were performed at 30 above ground
storage tanks. The purpose of the survey was to document locations
that do not meet the federal requirements for atmospheric corrosion.
Once found, evaluations were performed to identify, assess and document
current conditions, based on risk rank.
Nicor Gas Illinois
Performed atmospheric corrosion surveys at 3 under ground gas storage
fields for a total of 411 surveys of above-grade facilities. The purpose
of the survey was to document locations that do not meet the federal
requirements for atmospheric corrosion. Once found, evaluations
were performed to identify, assess and document current conditions,
based on risk rank.
Laclede Gas Company Missouri
Performed external corrosion direct assessment (ECDA) for Laclede Gas
Company, which is a natural gas utility.
Enbridge Oklahoma
Atmospheric corrosion evaluations were performed at 93 above grade
locations on a 10 diameter pipeline. The purpose of the survey was
to document locations that do not meet the federal requirements for
atmospheric corrosion. Once found, evaluations were performed to
identify, assess and document current conditions, based on risk rank
NIPSCO Indiana
Provided engineering support and services for an A/C mitigation study
along an 8.0 mile stretch of 16-inch and 12-inch diameter natural gas
pipeline. This study included the field survey, data analysis, PRCI modeling
and recommendations for mitigation and decoupling designs.
Valero/Premcor Indiana
Performed stray current analysis from D.C. traction rail lines and
provided recommendations to mitigate the D.C. on a 12 steel line.
This included installation of a temporary bond with a foreign pipeline
company.
GE Energy Villahermosa, Mexico
Provided field and engineering assistance to Mexicos oil company
(PEMEX Company) for the completion of external corrosion direct assessment
(ECDA) and customized training services related to indirect
inspection equipment for clients personnel.
Valero/Premcor Indiana
Performed a close interval survey on a 12 pipeline. Report included conclusions
and recommendations.
Valero/Premcor Indiana
Designed, installed, and tested a reverse current drainage switch to mitigate
stray current on an 8 line. This also included coordination with METRA to
install an impedance bond.
Valero/Premcor Indiana
Performed an atmospheric survey on above grade facilities in 4 areas of
Valeros system.
Valero/Premcor Indiana
Performed diagnostics test on 12 Hammond Terminal cathodic protection
rectifiers. These rectifiers are protecting 26 above ground storage tanks and
2 10 lines approximately 2,000 long. Report included conclusions and
recommendations.
Valero/Premcor Indiana
Performed stray current analysis from D.C. traction rail lines and provided
recommendations to mitigate the D.C. on an 8 steel line.
USG Washingtonville Pennsylvania
Field survey and design of corrosion control and stray current mitigation
for new 18 mile high pressure transmission pipeline.
Ameren Services Company Illinois
Performed integrity assessment of 2 pipelines. This assessment included
ECDA surveys, excavation for direct examination, and recommendations on
the findings.
Enbridge Oklahoma
Atmospheric corrosion evaluations were performed at 93 above grade locations
on a 10 diameter pipeline. The purpose of the survey was to document
locations that do not meet the federal requirements for atmospheric
corrosion. Once found, evaluations were performed to identify, assess and
document current conditions, based on risk rank.
NIPSCO Indiana
Provided engineering support and services for an A/C mitigation study
along an 8.0 mile stretch of 16-inch and 12-inch diameter natural gas pipeline.
This study included the field survey, data analysis, PRCI modeling and
recommendations for mitigation and decoupling designs.
Valero/Premcor Indiana
Performed stray current analysis from D.C. traction rail lines and provided
recommendations to mitigate the D.C. on a 12 steel line. This included
installation of a temporary bond with a foreign pipeline company.
GE Energy Villahermosa, Mexico
Provided field and engineering assistance to Mexicos Oil Company (PEMEX
Company) for the completion of external corrosion direct assessment
(ECDA) and customized training services related to indirect inspection
equipment for Clients personnel.
Valero/Premcor Indiana
Performed a close interval survey on a 12 pipeline. Report included conclusions
and recommendations.